during an HYD2 system loss, the PTU can still be used to lower the landing gear if:
kezdjen tanulni
there's minimum hydraulic quantity of 12% in the right reservoir
wingspan of emb170 and emb190
kezdjen tanulni
26m and 28,72m
Where is located the waste tank servicing panel:
kezdjen tanulni
on the rear right side of fuselage
dump switch button - what will happen after press in
kezdjen tanulni
ECS packs, recirculation fans to OFF. depressurize the cabin to 12400ft
How many channels does the cabin pressurization controller have
kezdjen tanulni
2
Where are installed the two ECS packs?
kezdjen tanulni
wing to fuselage fairing
APU model
kezdjen tanulni
Sunstrand APS 2300
How many inverters are in the aircraft?
kezdjen tanulni
1
What IDG 1 and IDG 2 normally power?
kezdjen tanulni
IDG 1 - AC BUS 1 and IDG 2 - AC BUS 2
T2 sensor
kezdjen tanulni
monitors the engine air inlet temperature
N1 sensor
kezdjen tanulni
provides the fan speed data for FADEC and vibration monitoring system
How many multi-function spoilers are on each wing?
kezdjen tanulni
5: 3 outboard and 2 inboard
How long will de-icing system remain on after icing is no longer detected?
kezdjen tanulni
5 minutes
The accumulator of emergency parking brake have sufficient pressure to provide:
kezdjen tanulni
6 full-brake applications
EGPWS: High-density red dots indicate:
kezdjen tanulni
terrain more than 2000ft above airplane altitude
What happened during pushback if speed will be higher than set and hydraulic systems 1 and 2 will be depressurized?
kezdjen tanulni
there will be EICAS message BRK LH (RH) FAULT or FAIL
the APU will automatically shutdown in flight if the following occur:
kezdjen tanulni
overspeed, underspeed, FADEC critical fault
What is the maximum continuous temperature for engine?
kezdjen tanulni
960°C
the navigation data base is updated every:
kezdjen tanulni
28 days
inertial reference system (IRS) computes:
kezdjen tanulni
airplane position, ground speed, heading and attitude
When is the wind shear detection activated?
kezdjen tanulni
between 10 and 1500ft
TRU ESS provides DC power to:
kezdjen tanulni
DC ESS BUS 3
Which ADSP will be heated when the batteries are the only electrical source?
kezdjen tanulni
ADSP 3
When the TCAS automatically reverts to TA only mode?
kezdjen tanulni
belów 900ft AGL during descent, or below 1100ft during climb
How long does the IESS take for alignment?
kezdjen tanulni
90 seconds
How many electrical sensors measure the fuel quantity?
kezdjen tanulni
13 in each tank
ILS covergae
kezdjen tanulni
10° to 25nm and 35° to 17nm
MEL - interval repair indication: A B C D
kezdjen tanulni
A - no standard, B - 3 days, C - 10 days, D - 120 days
What is included in the fire protection system (4 items)?
kezdjen tanulni
Engines, APU, Cargo compartments, lavatories
What happens when you pull the fire extinguisher handle? (4 items)
kezdjen tanulni
fuel, hydraulic, bleed air and crossbleed shutoff valves close
The fire handle illumination went off after discharging the bottle, but the EICAS warning ENG FIRE is still active. Is the fire still present?
kezdjen tanulni
Yes
What happens during detection of smoke in the lavatory (4 items)?
kezdjen tanulni
Master warning, EICAS warning - LAV SMOKE, alarm sound and light in the lavatory, flashing ORANGE light on rainbow lights
What happen if you press fire detection test buttom for more than 10s?
kezdjen tanulni
the APU will shut down
What does the AP quick disconnect button do?
kezdjen tanulni
disconnects the autopilot and stops any active trim command
Flaps/slats - sequence of deployment.
kezdjen tanulni
slats extend first and flaps retracts first
What happens in the intermediate position of flap/slat lever?
kezdjen tanulni
flaps/slats remain in the last selected position
What will happen if the CPT and F/O operate the control wheel pitch trim in the opposite direction?
kezdjen tanulni
captain has priority
What will happen if PBIT expires in flight?
kezdjen tanulni
no action is required
Total electricity loss - may we still operate flight controls?
kezdjen tanulni
yes, for at least 15 minutes through the backup power system
ETC, PCU, AFU - what do these acronyms stand for?
kezdjen tanulni
ETC - elevator thrust compensation. PCU - power control unit. AFU - artificial feel units
Strike overload - how many attempts are possible?
kezdjen tanulni
2 attempts
Slats/flaps and RAT deployed - does anything change?
kezdjen tanulni
the flap and slat operate in half speed. And max position 3
LOW1 in dual eng fail - why?
kezdjen tanulni
AC ESS BUS powers the AC Fuel PUMP 2A
Dripstick - what is it used for?
kezdjen tanulni
provide an alternate means for fuel measuring (mounted under each wing)
Ejector fuel pump - from which electrical bus is it fed?
kezdjen tanulni
it does not require electrical power to operate