CBT

 0    194 adatlap    jakubglowala8
letöltés mp3 Nyomtatás játszik ellenőrizze magát
 
kérdés English válasz English
total length EMB190
kezdjen tanulni
36,24m
length to nose wheel and length between wheels
kezdjen tanulni
4m and 13,8m
length to wingtip
kezdjen tanulni
20,04m
max. Ramp Weight
kezdjen tanulni
47,950kg
max. take-off weight
kezdjen tanulni
47,790kg
max. landing weight
kezdjen tanulni
43,000kg
max. zero fuel weight
kezdjen tanulni
40,800kg
max. Operational Flight Altitude
kezdjen tanulni
41,000ft
What is the max. APU start altitude?
kezdjen tanulni
30.000ft
To which altitude can APU be operated?
kezdjen tanulni
to 33.000ft
To which altitude bleed air from APU supply air conditioning and engine start-up?
kezdjen tanulni
air conditioning to 15.000ft and engine start-up to 21.000ft
engines in EMB 190
kezdjen tanulni
General electrics CF34-10E7 -10E5
normal and max. power take-off
kezdjen tanulni
normal - 17100 lbs of thrust and max. - 18500 lbs of thrust
How the reverse system works?
kezdjen tanulni
the system reverses the flow of the fan air by operation of sliding cascade vanes
Vlo for retraction and Vle
kezdjen tanulni
235 IAS and 265 IAS
wingspan EMB190
kezdjen tanulni
28,7 m
wheelspan EMB190
kezdjen tanulni
6m
fuselage width EMB190
kezdjen tanulni
3,01m
tailspan EMB190
kezdjen tanulni
12 m
tail height EMB190
kezdjen tanulni
10,5 m
height to engine EMB190
kezdjen tanulni
0,49m
fuselage height EMB190
kezdjen tanulni
3,35m
length of the cabin EMB190
kezdjen tanulni
almost 26 meters
cabin heigh EMB190
kezdjen tanulni
2m
Cargo bay 1 and 2 (volume and loading)
kezdjen tanulni
1 - 11m^2 1850kg. 2 - 9m^2 1650kg
The DC system is composed of:
kezdjen tanulni
3 Transformer rectifier units, 2 NiCad batteries and 1 DC external power input
When do we need to use DC GPU to start APU?
kezdjen tanulni
when #2 battery is not available or temperature is below -20 degrees C
liters of each tank - EMB190
kezdjen tanulni
6,550kg
total tank capacity
kezdjen tanulni
13100 kg
cabin ALT limit
kezdjen tanulni
8,000ft
hydraulic systems provide power to operate the:
kezdjen tanulni
flight controls, spoilers, landing gear, nose wheel steering, wheel brakes and thrust reverses
above what speed will wing anti-ice operate on the ground?
kezdjen tanulni
speed greater than 40 knots
What is MAUs?
kezdjen tanulni
Modular Avionics Units
Where are the indications for the cabin pressure displayed?
kezdjen tanulni
EICAS
In what tank is the DC pump located?
kezdjen tanulni
right wing tank
What is the potable water storage tank's maximum capacity?
kezdjen tanulni
110 liters
What is the usable capacity of the waste tank
kezdjen tanulni
95 liters
how is flushing toilet pressurized?
kezdjen tanulni
above 18,000ft differential pressure is used to flush the toilets. At or below 18,000ft a vacuum generator operates to create sufficient differential pressure
The pneumatic system indications are displayed on the
kezdjen tanulni
Environmental Control System synoptic page
When the cabin altitude HI warning message is issued?
kezdjen tanulni
when cabin altitude is equal to or higher than 9700ft
How many recirculation fans is the ECS equipped with?
kezdjen tanulni
2
When the emergency ram air valve is automatically opened?
kezdjen tanulni
in flight; PACKs-off; altitude is less than 25,000ft
How hot does it have to be for the Gasper Shutoff Valve to open?
kezdjen tanulni
35 degrees C
what is the ratio of total air flow entering the cockpit and cabin?
kezdjen tanulni
52% fresh air and 48% recirculated air
When the EICAS Caution message CABIN DIFF PRESS FAIL will be displayed?
kezdjen tanulni
when the cabin differential pressure is higher than 8.5 psi or lower than -0.3 psi.
differential pressure setting below and above 37.000ft cruise flight level
kezdjen tanulni
below 37.000ft - 7.8 psi. Above 37.000ft - 8.4 psi.
above which speed Mach Trim will automatically engage?
kezdjen tanulni
above. 70 Mach number
to which degrees the take-off mode pitch is limited
kezdjen tanulni
minimum of 8 degrees and a maximum of 25 degrees
when within 200ft radio altitude the maximum bank angle is reduced to what degree?
kezdjen tanulni
+/- 5 degrees
when can Autothrottles be engaged in flight?
kezdjen tanulni
when the airplane is 400ft AGL or above
when can auto throttles Retard mode be activated
kezdjen tanulni
when at or below 30ft on radio altimeter
When Climb mode changes to CRZ mode?
kezdjen tanulni
when aircraft is for 90 seconds at preselected altitude and airspeed is within 5kt from preselected airspeed
bank angle limit in automatic bank mode BANK
kezdjen tanulni
+/- 17°
how the AP will act at different bank angles?
kezdjen tanulni
belów 6° will level wings; above 6° and below 35° will holds present bank angle; above 35° will maintain bank angle of 35°
what is the limit of the flight path reference line selected by the FPA selector?
kezdjen tanulni
+/- 9,9 degrees
Take-off mode pitch limits
kezdjen tanulni
minimum of 8 degrees and max of 18 degrees. SPEED - max Vfe-5kt and min Vshaker+10kt
How long after landing the TO mode can be enabled?
kezdjen tanulni
after 5 seconds on the ground (main gear weight on wheels)
above which altitude speed will change between IAS and Mach?
kezdjen tanulni
close to 29,000 ft
Range of vertical speed mode
kezdjen tanulni
-8000 ft/min to +6000 ft/min
ONE click of vertical speed selector (thumbwheel)
kezdjen tanulni
below 1000ft = 50ft/min; above 1000ft/min = 100ft/min
What speed after Go-around with both engines operating?
kezdjen tanulni
Vref + 20kt
What speed after Go-around with an engine inoperative?
kezdjen tanulni
Vac (approach climb)
Speed limits in GA mode
kezdjen tanulni
max Vref - 5kt min Vshaker + 10kt
Above which altitude windshear protection is disabled?
kezdjen tanulni
above 1500ft AGL
To how many degrees is the Elevator Thrust Compensation Function (ETC) limited?
kezdjen tanulni
it is limited to +/- 5 degrees
What are the five tic marks on stabilizer scale?
kezdjen tanulni
11°, 7,25°, 3,5°, 0,25°, 4°
Green scale (band) on stabilizer scale
kezdjen tanulni
from 2° to 4° UP
How is the pitch trim limited to prevent pitch trim runaway?
kezdjen tanulni
manuał pilot trim is limited to 3 seconds
How much will the rudder move in direct mode?
kezdjen tanulni
it will move 30° from neutral
max speed for flaps FULL
kezdjen tanulni
165 KIAS
max speed for flaps 5 and 4
kezdjen tanulni
180 KIAS
max speed for flaps 3
kezdjen tanulni
200 KIAS
max speed for flaps 2
kezdjen tanulni
215 KIAS
max speed for flaps 1
kezdjen tanulni
230 KIAS
max speed for flaps 0
kezdjen tanulni
Vmo / Mmo
max speed for flaps 1,2,3,4,5, full
kezdjen tanulni
230, 215, 200, 180, 180, 165 KIAS
max flaps for take-off
kezdjen tanulni
flaps 4
flaps for go-around
kezdjen tanulni
flaps 4
how many are flaps and slats actuators?
kezdjen tanulni
4 flaps actuators per side (8) and 8 slats actuators per side (16)
max slat and flap deflection
kezdjen tanulni
slat 25°; flap 37°
max deployment of slats and flaps during RAT operation
kezdjen tanulni
position 3
Conditions for automatic deployment of ground spoilers
kezdjen tanulni
1. weight on wheels on the ground. 2. wheelspeed is above 45kt or airspeed is above 60kt 3. thrust lever angle is below 26 degrees.
Deployment of automatic ground spoilers - deflection
kezdjen tanulni
multifunction spoilers - 40°; ground spoilers - 60°
Conditions for automatic retraction of ground spoilers
kezdjen tanulni
wheel speed below 45kt for at least 5 seconds. OR throttles moved beyond 35 degrees (TLA)
extension limit of speed brakes when handle position is in OPEN
kezdjen tanulni
30°
max deflection of flaps to use speed brakes
kezdjen tanulni
slat/flap position 2 or above
minimum speed for using speed brakes
kezdjen tanulni
180 KIAS
condition for automatic speed brakes retraction
kezdjen tanulni
Thrust lever angle (TLA) beyond 70 degrees
How are emergency lights powered?
kezdjen tanulni
by 6 Emergency Lights Power Units (ELPU)
How long can Photoluminescent Stripes illuminate?
kezdjen tanulni
about 7 hours when fully charged
What are the external emergency lights?
kezdjen tanulni
3 overwing lights on each side + red light on escape slides
When sterile cockpit lights should be ON?
kezdjen tanulni
during takeoff through FL100 and during descent FL100 or below
What are the 5 colors and lights of rainbow lights?
kezdjen tanulni
YELLOW - pilot sterile cockpit; GREEN - Pilot; RED - Pilot EMERGENCY; BLUE - Pax; ORANGE - Toilet
How many lights are in cargo area?
kezdjen tanulni
7 in forward and 6 in aft area
How many are Air Data Smart Probes?
kezdjen tanulni
4x ADSPs and 2x TAT probes
Air Data Smart Probes consist of:
kezdjen tanulni
Total pressure port, 2 Alpha Ports, 2 Drain Holes
What power is required for Electronic Display System?
kezdjen tanulni
28 Volt DC power
What is FPA Acceleration Pointer
kezdjen tanulni
provides information of the acceleration and deceleration rates along the flight path
Pitch limit indications with colors:
kezdjen tanulni
GREEN: from 1.2 of Vstall to 1.13 of Vstall. AMBER: from 1.13 of Vstall to Vshaker. RED: at or below Vshaker
Low Bank Arc limits
kezdjen tanulni
from 0° to 17°
pitch attitude when red chevron will appear
kezdjen tanulni
30 degrees NOSE UP or 20 degrees NOSE DOWN
to which altitude Radar Altimeter works?
kezdjen tanulni
up to 2500 ft AGL
How many Radar Altimeters has LOT installed?
kezdjen tanulni
2
RALT 1 or RALT 2 FAIL
kezdjen tanulni
failure of Radar Altimeter displayed on EICAS
Above what speed during takeoff speeds: V1, Vr, V2, Vfs will appear?
kezdjen tanulni
above 30kt during take-off
When the landing speeds appear on the side of the airspeed tape?
kezdjen tanulni
when FMS is in landing mode or the airspeed drops between 230kt and 190kt
Airspeed Trend Vector margin
kezdjen tanulni
10 seconds
Mach speed Indications
kezdjen tanulni
speed above. 450 mach it will appear. when the speed is less than. 400 Mach it will disappear
Yellow and Red bars on speed tape
kezdjen tanulni
YELLOW: speed between 1,13 Vstall and 1,05 Vstall. RED: at or below Vshaker
Automatic transition from ROLL to TRACK mode
kezdjen tanulni
airspeed is more than 100kt and bank angle is less than 3 degrees for more than 10 seconds.
How many VHF Comm Antennas are?
kezdjen tanulni
3
How many RAMP inter phone inputs are?
kezdjen tanulni
3
How many DVDRs are installed?
kezdjen tanulni
2 (one in forward electronic bay and second in aft electronic bay)
DVDR capability
kezdjen tanulni
2h audio information, 2h digital communication, 25h flight data
When Radar Altitude window displays height?
kezdjen tanulni
when the airplane is below 2500ft and above 20ft AGL
When "approach minimums" call will be?
kezdjen tanulni
80 ft above pilot set minimums
Altitude Trend Vector margin
kezdjen tanulni
6 seconds
range in which green pointer of vertical speed shows fpm
kezdjen tanulni
between +550fpm and +4000fpm
to which altitude can APU provide power?
kezdjen tanulni
to FL330
Each source of AC power provides:
kezdjen tanulni
115 V, 400Hz, 3-phase power
What is the load of engine or APU?
kezdjen tanulni
each has a load of 40kVA
What is the load of RAT?
kezdjen tanulni
RAT has a load of 15kVA
How long RAT needs to deploy and start producing the power?
kezdjen tanulni
8 seconds, during this time the batteries are used as a backup
min speed for RAT ti supply AC/DC ESS BUSES
kezdjen tanulni
minimum of 130 knots
How the inverters work?
kezdjen tanulni
they convert 28 V (DC) battery power to 115 V (AC) power
How the TRUs work?
kezdjen tanulni
they are rated at 300A. they convert 115 V (AC) power to 28 V (DC) power
describe NiCad battery
kezdjen tanulni
22,8 V (DC), 27A
for how long will the batteries supply essential loads?
kezdjen tanulni
for 10 minutes
2 conditions fot the battery to display green in Electrical Synoptic Page
kezdjen tanulni
temperature is below 70°C and voltage is greater than 18V (DC)
How long does the APU need to become available?
kezdjen tanulni
3 seconds after the RPM reaches 95% during APU start.
Fire detection for the engine
kezdjen tanulni
there are 8 pneumatic fire detectors in 2 loops for each engine
Fire detection for the APU
kezdjen tanulni
there are 2 pneumatic fire detectors in 2 loops.
On the ground, after fire detection in APU, after what time the system will automatically shut down the APU?
kezdjen tanulni
after 10 seconds.
how many smoke detectors are in the cargo compartments?
kezdjen tanulni
There are 4 detectors in the forward compartment and 3 in the aft compartment.
How the fire extinguisher bottles work in cargo compartments?
kezdjen tanulni
high-rate bottle - after pressing button. In flight after 60 seconds it will automatically discharges the low-rate (for 60min), on the ground it is necessary to press the button second time.
How to discharge extinguisher bottles in cargo compartment without detecting the smoke first?
kezdjen tanulni
by pressing the button it will armed, pressing second time (within 2 minutes) it will discharge the high-rate bottle
if the flight attendant performs lavatory fire test, how long will the EICAS warning message illuminate?
kezdjen tanulni
for 7 seconds
describe N1
kezdjen tanulni
Single-stage low-pressure fan is driven by a four-stage low-pressure turbine.
describe N2
kezdjen tanulni
Ten-stage axial-flow compressor is driven by a two-stage high-pressure turbine.
How is the Inter Turbine Temperature (ITT) measured?
kezdjen tanulni
It is measured by 5 thermocouples located in the low-pressure turbine.
How many are fuel injectors in Fuel Distribution System?
kezdjen tanulni
18
What happened if you momentarily turn the start selector knob to start position?
kezdjen tanulni
pressurized air is sent to the air turbine starter, this rotates the engine rotor via the accessory gearbox.
When aircraft closes the Starter Control Valve during engine starting?
kezdjen tanulni
at approximately 50% N2
Above what temperature the hot start protection will terminate start?
kezdjen tanulni
when the ITT rises above 740°C
WML (indication)
kezdjen tanulni
WINDMILL - indicates an engine flameout and the respective engine is windmilling
Normal and Cautionary Operating Range of Engine's Vibration
kezdjen tanulni
Normal - 0,0-3,9 and Cautionary - 4,0-5,0
Vibration indications just after engine start
kezdjen tanulni
for the first 60 seconds, engine vibration will be amber for values equal to or greater than 5.0
Ignition system for each engine
kezdjen tanulni
2 ignition exciters, 2 ignition leads, 2 igniters
How much is the full travel of the thrust levers?
kezdjen tanulni
85 degrees
What are the two detents in throttle quadrant?
kezdjen tanulni
70° TO/GA and 12° Min reverse
What does it mean ENG 1 REV TLA FAIL on EICAS?
kezdjen tanulni
that means that the throttles can be put in reverse in flight or cannot be put into reverse on the ground
Describe APU
kezdjen tanulni
The APU has a single stage compressor and a dual stage turbine.
from which wing tank is fuel supplied to the APU?
kezdjen tanulni
from wing tank 2
What is the minimum battery temperature for APU start?
kezdjen tanulni
-20°C
APU starting cycle limits
kezdjen tanulni
First and second cycles - 60s ON, 60s OFF. Third cycle - 60s ON, 5 min OFF
max rotor speed of APU
kezdjen tanulni
108%
max. EGT for APU during start and during continuous
kezdjen tanulni
start - 1032°C, continuous - 717°C
Minimum temperature operational limit for APU
kezdjen tanulni
-54°C
For how many RPM FADEC initiates ignition during APU start on the ground and in flight?
kezdjen tanulni
on the ground to 6%, during flight between 7% and 17%
When will you see appearance of APU green symbol on synoptic page?
kezdjen tanulni
at approximately 50% RPM (when FADEC commands starter cutout)
When both electrical and pneumatic power is available after APU start?
kezdjen tanulni
3 seconds after the APU reaches 95%
When the FUEL 1 (2) LO LEVEL indication will display on EICAS?
kezdjen tanulni
when 400kg of fuel remain in the respective tank
When the FUEL IMBALANCE will display on EICAS?
kezdjen tanulni
when imbalance is equal or greater than 360kg, It remains displayed until the imbalance is reduced to 45 kg
What pumps are in each wing?
kezdjen tanulni
1x ejector pump, 1x AC boost pump, 3x scavenge ejector pumps. And a DC pump only in the right wing
Fuel quantity Scale Colors
kezdjen tanulni
GREEN - 601-6550kg; AMBER - 400-600kg; RED - 0-399kg
Fuel temperature scale colors:
kezdjen tanulni
NORMAL -39°C or higher; AMBER -40°C or below
What is the freeze point for Jet A-1 fuel
kezdjen tanulni
-49°C
Kilograms to Pounds (lbs)
kezdjen tanulni
x2 + 10%
What powers the refueling system if the power selection switch is in the NORMAL or BATTERY position?
kezdjen tanulni
NORMAL - DC BUSES 1 and 2 ; BATTERY - HOT BATTBUS 2
Handwheel steering
kezdjen tanulni
up to 76° to 10 kt. over 26kt up to 20°. over 89kt decreases to 7°
Rudder steering
kezdjen tanulni
up to 7°
Conditions when "LANDING GEAR" aural warning cannot be silenced:
kezdjen tanulni
with flap position 5 or FULL; with flap lever in any position: 1) radio altitude below 700ft AGL. 2a) thrust lever is set below 38° (for 2 engines). 2b) thrust lever is set below 57° (for 1 engine INOP)
When is the Locked Wheel Protection ON?
kezdjen tanulni
when the speed is above 30 kt
When is the Anti Skid ON?
kezdjen tanulni
when the speed is above 10 kt
When is the Touchdown Protection OFF?
kezdjen tanulni
wheel speed more than 50kt OR 3 seconds after WOW detects on the ground
Oxygen cylinder bottles for flight deck crew
kezdjen tanulni
77ft^3 ; 1850psi at 21°C
How many masks are in the aircraft in the row?
kezdjen tanulni
3 masks in right side and 2 masks in the left side PSUs
For how long will the oxygen flow in the passengers' masks
kezdjen tanulni
for about 14 minutes and cannot be shut off
At what altitude will the masks deploy?
kezdjen tanulni
between 14,000ft and 14,750ft
To what altitude can PBE be used?
kezdjen tanulni
to 25,000ft
What is the capacity of the POBs cylinders?
kezdjen tanulni
312 liters
What is the pressure required in the POBs?
kezdjen tanulni
at least 1200psi to 1800psi
describe two outlets of POB
kezdjen tanulni
1) 2 liters per minute for walk-around use. 2) 4 liters per minute for first aid use
Hydraulic fluid and pressure
kezdjen tanulni
Each system use Skydrol hydraulic fluid and operate at pressure of 3000psi
Hydraulic systems pumps
kezdjen tanulni
System 1 and 2 have one engine driven and one electric driven pump. System 3 has 2 electric driven pumps (A and B)
When the Hydraulic ELEC PUMP is set on AUTO, when will it be activated?
kezdjen tanulni
flaps position greater than 00 AND thrust lever to take-off thrust OR groundspeed greater than 50kt
Hydraulic reservoir for system 1 and 2
kezdjen tanulni
System 1 - 12,3l; System 2 - 14,75l
When will the wing anti-ice operate on the ground?
kezdjen tanulni
wheel speed greater than 40kt
Engine Anti-Ice on the ground:
kezdjen tanulni
temperature 5-10°C - on the MCDU - ENG and there is visible moisture up to 1700ft AFE. Temperature below 5°C on the MCDU - ALL + visible moisture
Engine Anti-Ice
kezdjen tanulni
it operates through bleed air from low stage valve (5th stage)
Conditions for automatic Anti-Ice activation
kezdjen tanulni
1. altitude below 22000ft. 2. air temp. inside specific limits. 3. vertical speed within 200 ft/min. 4. airspeed between 150 and 320 knots. System will activate if these conditions are true for 2 min.
What Embraers does LOT have?
kezdjen tanulni
170STD, 175STD, 175LR, 190STD, 195LR, 195AR
How far is ILS certified?
kezdjen tanulni
up to 18nm
5 approaches - preparation:
kezdjen tanulni
LOC - v/l, nav, FPA. VOR - v/l, ..., FPA. VOR(M) - FMS (preview), APP ILS - FMS (preview)->v/l, APP. RNP - FMS, APP

Kommentár közzétételéhez be kell jelentkeznie.